Fuwei is a distinguished Manufacturer and Supplier in China, specializing in professional IP67 ranging sensors, industrial ranging sensors, and capacitive tag sensors. We extend a warm welcome to both new and existing customers, inviting them to join us in forging a brighter future through ongoing collaboration.
The Photoelectric sensors Equipped with multiple transition light point adjuster, the distance can be accurately set;
Equipped with automatic anti-interference function;
The BGS/FGS function allows for easy, more stringent Settings.
The Photoelectric sensors Equipped with multiple transition light point adjuster, the distance can be accurately set;
Equipped with automatic anti-interference function;
The BGS/FGS function allows for easy, more stringent Settings.
Part number:FSD23-150-RS485
Measurement center distance:150mm
Measurement range:±100mm
Linearity:±0.5%F.S.
Repeatability:60μm
Control output:NPN/PNP max.100mA/DC30V ((Residual voltage 1.8 V max.)
Supply voltage:24VDC, Sampling period: 500 μs, Averaging: 64,Measuring distance:Center of range, Testing object: White ceramic
Analog voltage output:Output 0-10V , output impedance 100ΩAnalog current output:Output 4-20mA, allowable load resistance below 300Ω
Protection:IP67
Operating Temp./Humid.:-10~50⁰C / 35 ~ 85% RH without freasing or condensation
Part number:FSD23-150-AV
Measurement center distance:150mm
Measurement range:±100mm
Linearity:±0.5%F.S.
Repeatability:60μm
Control output:NPN/PNP max.100mA/DC30V ((Residual voltage 1.8 V max.)
Supply voltage:24VDC, Sampling period: 500 μs, Averaging: 64,Measuring distance:Center of range, Testing object: White ceramic
Analog voltage output:Output 0-10V , output impedance 100ΩAnalog current output:Output 4-20mA, allowable load resistance below 300Ω
Protection:IP67
Operating Temp./Humid.:-10~50⁰C / 35 ~ 85% RH without freasing or condensation
Part number:FSD23-150-AA
Measurement center distance:150mm
Measurement range:±100mm
Linearity:±0.5%F.S.
Repeatability:60μm
Control output:NPN/PNP max.100mA/DC30V ((Residual voltage 1.8 V max.)
Supply voltage:24VDC, Sampling period: 500 μs, Averaging: 64,Measuring distance:Center of range, Testing object: White ceramic
Analog voltage output:Output 0-10V , output impedance 100ΩAnalog current output:Output 4-20mA, allowable load resistance below 300Ω
Protection:IP67
Operating Temp./Humid.:-10~50⁰C / 35 ~ 85% RH without freasing or condensation
Part number:FSD23-150-RS485
Measurement center distance:35mm
Measurement range:±15mm
Linearity:±0.1%F.S.
Repeatability:6μm
Control output:NPN/PNP max.100mA/DC30V ((Residual voltage 1.8 V max.)
Supply voltage:24VDC, Sampling period: 500 μs, Averaging: 64,Measuring distance:Center of range, Testing object: White ceramic
Analog voltage output:Output 0-10V , output impedance 100ΩAnalog current output:Output 4-20mA, allowable load resistance below 300Ω
Protection:IP67
Operating Temp./Humid.:-10~50⁰C / 35 ~ 85% RH without freasing or condensation
Part number:FSD23-100-RS485
Measurement center distance:35mm
Measurement range:±15mm
Linearity:±0.1%F.S.
Repeatability:6μm
Control output:NPN/PNP max.100mA/DC30V ((Residual voltage 1.8 V max.)
Supply voltage:24VDC, Sampling period: 500 μs, Averaging: 64,Measuring distance:Center of range, Testing object: White ceramic
Analog voltage output:Output 0-10V , output impedance 100ΩAnalog current output:Output 4-20mA, allowable load resistance below 300Ω
Protection:IP67
Operating Temp./Humid.:-10~50⁰C / 35 ~ 85% RH without freasing or condensation
Part number:FSD23-35-RS485
Measurement center distance:35mm
Measurement range:±15mm
Linearity:±0.1%F.S.
Repeatability:6μm
Control output:NPN/PNP max.100mA/DC30V ((Residual voltage 1.8 V max.)
Supply voltage:24VDC, Sampling period: 500 μs, Averaging: 64,Measuring distance:Center of range, Testing object: White ceramic
Analog voltage output:Output 0-10V , output impedance 100ΩAnalog current output:Output 4-20mA, allowable load resistance below 300Ω
Protection:IP67
Operating Temp./Humid.:-10~50⁰C / 35 ~ 85% RH without freasing or condensation
Part number:FSD23-35-AV
Measurement center distance:35mm
Measurement range:±15mm
Linearity:±0.1%F.S.
Repeatability:6μm
Control output:NPN/PNP max.100mA/DC30V ((Residual voltage 1.8 V max.)
Supply voltage:24VDC, Sampling period: 500 μs, Averaging: 64,Measuring distance:Center of range, Testing object: White ceramic
Analog voltage output:Output 0-10V , output impedance 100ΩAnalog current output:Output 4-20mA, allowable load resistance below 300Ω
Protection:IP67
Operating Temp./Humid.:-10~50⁰C / 35 ~ 85% RH without freasing or condensation